凯发k8国际

微量杂质分析解决方案 - 应用

{"hasMore":true,"more":{"id":"tbaleAnchor_more","label":"\u66f4\u591a"}} {"hasMore":true,"more":{"id":"tbaleAnchor_more","label":"\u66f4\u591a"},"anchors":[{"id":"tbaleAnchor_applications","label":"\u5e94\u7528"},{"id":"tbaleAnchor_technical","label":"Technical Documents"},{"id":"tbaleAnchor_manual","label":"Manuals"}]} {"key":5100,"max":null,"filter":"Applications"} {"title":"\u5e94\u7528","columnTitle":"\u5e94\u7528","source":"product","key":5100,"filter_types":["applications","application_note","posters"],"config_list":[],"anchor":"tbaleAnchor_applications","filter":true} {"title":"Technical Documents","columnTitle":"Technical Documents","source":"product","key":5100,"filter_types":["technical","technical_reports","white_papers","primers"],"config_list":[],"anchor":"tbaleAnchor_technical","filter":true} {"title":"Manuals","columnTitle":"Manuals","source":"product","key":5100,"filter_types":["manuals"],"config_list":[],"anchor":"tbaleAnchor_manual","filter":true}

解决方案一

 

乙烯丙烯中微量CO、CO2分析系统配置

 

序号 配置 数量
1 GC主机 1
2 十通阀 1
3 六通阀 1
4 色谱柱 3
5 FID检测器 1
6 甲烷转化炉 1

 

  • 特点

    • • 十通阀反吹放空烯烃及重组分,增强系统稳定性
    • • 微量CO、CO2转化成甲烷经FID检测
    • • 六通阀设计避免空气对CO干扰
  • 谱图

    色谱图

    色谱图

 

解决方案二

 

甲烷中微量CO、CO2分析系统配置

 

序号 配置 数量
1 GC主机 1
2 十通阀 1
3 六通阀 1
4 色谱柱 3
5 FID检测器 1
6 甲烷转化炉 1

 

  • 特点

    • • 十通阀反吹放空重组分,缩短分析时间
    • • 六通阀放空甲烷,避免对CO2干扰
    • • 微量CO、CO2转化成甲烷经FID检测
  • 谱图

    色谱图

    色谱图

 

解决方案三

 

乙烯丙烯中微量COS分析系统配置

 

序号 配置 数量
1 GC主机 1
2 分流/不分流进样口(惰性化) 1
3 六通阀(惰性化) 1
4 色谱柱 1
5 FPD检测器 1

 

  • 特点

    • • 进样口、阀、定量环等样品流路惰性化处理
    • • FPD检测器双聚焦系统,实现高灵敏度检测
  • 谱图

    色谱图

    色谱图

 

解决方案四

 

SCD检测器痕量硫化物分析系统配置:

 

序号 配置 数量
1 GC主机 1
2 分流/不分流进样口(惰性化) 1
3 六通阀(惰性化) 1
4 色谱柱 1
5 SCD检测器 1

 

  • 特点

    • • 进样口、阀、定量环等样品流路惰性化处理
    • • 高灵敏度SCD检测器
    • • 操作简单、维护方便
  • 谱图

    色谱图

    色谱图